Next: C
Up: LAS and ANALYSE Messages
Previous: LAS and ANALYSE Messages
Contents
Index
- E-ACCUMULATE, Coordinate systems are not compatible
LAS, SUM or ACCUMULATE commands. Two observations had different
coordinate systems and could not be added.
User action : Convert them to a
common coordinate system, or use the SET NOMATCH command to turn
off position checking.
- E-ACCUMULATE, Different calibrations
LAS, SUM or ACCUMULATE commands. Two observations were done with
different major calibration parameters (Beam Efficiency and possibly
Forward Efficiency) and could not be added.
User action : May be they were
not on the same temperature scale. The weighting (and values) is
incorrect in such a case. Modify the corresponding calibration parameter
and retry. You may bypass this calibration checking by using command SET
CAL OFF.
- W-ACCUMULATE, Different reference channels R: <Real> T: <Real>
LAS, SUM or ACCUMULATE commands. Two spectra were added with the
ALIGN mode CHANNELS, but had different reference channels,
and hence possibly different velocity or frequency scales.
User action :
Check if these spectra were to be added. If you want to add them and
preserve a common velocity (or frequency) scale, use the ALIGN mode
VELOCITY (resp. FREQUENCY).
- W-ACCUMULATE, Different resolution R: <Real> T: <Real>
LAS, SUM or ACCUMULATE commands. Two spectra were added with the
ALIGN mode CHANNELS, but had different resolutions and hence
possibly different velocity or frequency scales.
User action : Check if these
spectra were to be added. If you want to add them and preserve a common
velocity (or frequency) scale, use the ALIGN mode VELOCITY
(resp. FREQUENCY).
- W-ACCUMULATE, Different rest frequencies R: <Real> T: <Real>
LAS, SUM or ACCUMULATE commands. Two spectra were added with the
ALIGN mode CHANNELS or VELOCITY, but had different rest
frequencies and hence possibly different velocity or frequency scales.
User action : Check if these spectra were to be added. If these spectra
correspond to the same molecular line, use the MODIFY FREQUENCY to
reset a common velocity scale and the ALIGN mode VELOCITY
before adding them.
- W-ACCUMULATE, Different velocities R: <Real> T: <Real>
LAS, SUM or ACCUMULATE commands. Two spectra were added with the
ALIGN mode CHANNELS or FREQUENCY, but had different
velocities and hence possibly different velocity or frequency scales.
User action : Check if these spectra were to be added. If these spectra
correspond to the same object, use the MODIFY VELOCITY to reset a
common rest frequency scale and the ALIGN mode FREQUENCY
before adding them.
- W-ACCUMULATE, Drift not aligned in position
LAS, SUM or ACCUMULATE commands. Two continuum drifts were added
but are not coincident in position.
User action : Select POSITION
alignment using command SET, and retry.
- W-ACCUMULATE, Origin table overflow
LAS, SUM or ACCUMULATE commands. Too many spectra were added and
the list of original scan numbers is full. Scan numbers of any other
added spectrum will be lost.
User action : none. The spectrum still contains
the sum the all desired spectra, only the list is wrong.
- E-ACCUMULATE, Positions are not compatible
LAS, SUM or ACCUMULATE commands. Two spectra have different
positions and have not been added.
User action : If you want to add them, use
the SET NOMATCH command before.
- E-ACCUMULATE, <String> ranges do not intersect
LAS, SUM and ACCUMULATE commands. Two spectra were to be added with
the ALIGN mode specified by <String> and INTERSECT
mode, but do not overlap.
User action : what do you want to add ?...
- W-ACCUMULATE, Spectra not aligned in sky frequency
R: <Real> T: <Real>
LAS, SUM and ACCUMULATE commands. Two spectra were added with ALIGN mode CHANNELS, but have a different sky frequency scale.
User action : use the SET ALIGN FREQUENCY if you want to preserve a
common frequency scale.
- E-ACCUMULATE, Too many channels requested
LAS, SUM and ACCUMULATE commands. Two spectra were added with ALIGN mode COMPOSITE, but the final spectrum requires more
channels than reserved in the program.
User action : most likely you are
trying to make a composite spectrum with two unrelated frequency bands,
such as CO and HCN... Note also that making composite spectra is not
necessary to plot a few GHz from a spectral survey.
- E-ADD, Cannot add Continuum with Line data.
LAS, ACCUMULATE command: The two observations are not of the same
kind. SUM command: The index contains observations of different
kinds.
User action : It is time to get some rest and a cup of coffee...
- W-ADD, Gives sum of spectra for EQUAL weight
LAS, ACCUMULATE command: This command gives the sum of the spectra,
not the average.
User action : This behaviour is consistent with that of SUM which gives the average over the index. Using several ACCUMULATE
commands, and then dividing the final result by the number of added
observations yields the same result as SUM.
- W-ADD, Still experimental for Continuum
LAS, ACCUMULATE and SUM commands.
User action : Poor guinea pig... Do
not worry too much, it usually works fine, but we would appreciate
receiving detailed comments if you find something bizarre.
- E-BASE, Insufficient memory for work space
LAS, BASE command. The work space to compute the best fit
polynomial could not be dynamically allocated because the program
exhausted its virtual memory quota.
User action : i) clear any plot and
restart. ii) run CLASS in a single process (not from a sub-process).
iii) Ask your system manager to extend the virtual memory limit.
- E-BASE, No line window
LAS, BASE command. No line window has been defined.
User action :
define one or more windows using the SET WINDOW command.
- E-BASE, No valid baseline
LAS, BASE command : the windows covers the full spectrum and leave
no channels to compute the baseline
User action : define windows which do not
cover the spectrum, or (if possible) compute the baseline from another
backend and use the command BASE LAST to apply it to this spectrum.
- E-BASE, Sinus not converged
LAS, BASE command with SINUS method. The minimization routine
failed to converge to a valid solution.
User action : The solution may still
be sensible, look at it. If not, retry with different guesses.
Next: C
Up: LAS and ANALYSE Messages
Previous: LAS and ANALYSE Messages
Contents
Index
Gildas manager