Next: G through I
Up: LAS and ANALYSE Messages
Previous: D and E
Contents
Index
- E-FILE, IN OUT or BOTH please
LAS, FILE command. The first argument is incorrect (typing error).
- E-FILE, No default is provided for the file name
LAS, FILE command. The second argument (file name) is missing.
- I-FIND, <Integer> observations found
LAS, FIND command, information message.
- E-FIND, Nothing found
LAS, FIND command, information message. Variable FOUND is
reset to 0.
User action : if you believe something should have been found,
check the various selection criteria. One is probably different from what
you had in mind.
- I-FIND, <Integer> observations in index
LAS, FIND command with argument APPEND, information message.
The index has been appended and compressed to avoid duplicate entries to
a given scan.
- W-FITCONT, Solution not converged
W-FITGAUSS, Solution not converged
W-FITNH3, Solution not converged
W-FITSHELL, Solution not converged
ANALYSE, GAUSS command. The minimization failed to converge to a
valid solution.
User action : Look at the results using command FIT. If
they seem good enough, use command ITERATE until convergence is
reached. If the warning persists, may be the problem is badly defined
and the solution unreliable.
- E-FITNH3, Unit X must be Velocity
LAS, GAUSS command for method NH3. The X unit must be
velocity to fit NH hyperfine structure.
User action : use command SET UNIT X V, reset new guesses using command LINES and retry.
- E-FITSHELL, No baseline removed
ANALYSE, GAUSS command, SHELL method. A base line must have
been removed before fitting.
User action : use the BASE command to
remove a baseline, and retry.
- E-FITSHELL, Unit X must be Frequency
ANALYSE, GAUSS command, SHELL method. ``Circumstellar
shells'' like profile fitting is only possible in Frequency units.
User action : use command SET UNIT X F, check the initial guesses and
retry.
- F-FIX, Current index is full
LAS, FIND command, usually with APPEND argument. Too many
spectra match the current selection criteria, and the index is too large.
Some spectra have been omitted from the index.
User action : Restrict the
search by adding more severe selection criteria. Note in any case that
you will have troubles processing the connected input file because it
contains too many spectra. It would be wise to split this file in smaller
ones, according to selected criteria.
- E-FIX, More than <Integer> observations found
LAS, GET or other commands involving index finding operations, such
as DROP. There are too many scans matching the requested criteria.
Most likely, this error is due to an incoherent input file which contains
twice the same scan (number AND version).
User action : It is possible to get
rid of the duplicate scans by the following recipe. i) define a new
output file to receive the valid spectra. ii) use a FIND/ALL
without any selection criterium. iii) use the GET NEXT command to
retrieve scans. iv) use the WRITE command for all scans but the
duplicate scans that you should either skip or write under a new scan
number (WRITE Number command). The new output file should be
correct. If not see ``Recovering Corrupted Data Files''.
- E-FIX, Read error
LAS, FIND or other commands involving index finding operations.
This may be due to a lack of input file (not all commands are explicitly
protected against this specific mistake), but also to hardware problems.
User action : after checking for the input file, retry the operation. If the
error persists, submit an SPR, and see ``Recovering Corrupted Data
Files''
- W-FOLD, Cannot fold a single phased spectrum
LAS, FOLD command. The current spectrum was not observed in
frequency switching mode, so that it cannot be folded.
- E-FOLD, No channels left in spectrum
LAS, FOLD command. The align mode is INTERSECT, and the
frequency switch is so large that no channel overlap from one phase to
the others.
User action : Set the align mode to COMPOSITE, and redo the
command.
- E-FSHELL, Wrong Arguments : <Real>
ANALYSE, GAUSS command with method SHELL. The minimization
routines went into a forbidden region for the parameters. The
minimization aborts.
User action : retry the fit with a different choice of
input parameters.
Next: G through I
Up: LAS and ANALYSE Messages
Previous: D and E
Contents
Index
Gildas manager
2014-07-01