next up previous contents index
Next: R Up: LAS and ANALYSE Messages Previous: M   Contents   Index

N-Q

F-NOISE, No spectrum in memory
LAS, NOISE command. The command was specified without arguments, but there is no spectrum in the R memory to estimate a noise level.
User action : Specify a noise level, or get a spectrum in R.
I-OUTPUT, <String> is reopened
LAS, FILE OUT command, information message.
I-OUTPUT, <String> successfully opened
LAS, FILE OUT command, information message.
W-OUTPUT, No output file opened
LAS, FILE OUT command. The specified file could not be opened, or is not a valid CLASS file, but no previous output file has been reopened.
F-OUTPUT, Non standard file <String>
LAS, FILE OUT command. The specified file could be opened, but is not a CLASS data file.
User action : probably the file name has been mistyped.
E-OUTPUT, Old format not supported
LAS, FILE OUT command. The specified file has an old data format, and cannot be used for output.
User action : this file can be used for input. You may create a copy of it in new format by reading and writing to a new file all observations contained in it.
F-OUTPUT, Open error file <String>
LAS, FILE OUT command. The specified output file could not be opened. The message if followed by more details about the specific reason for the open failure. The most likely reasons are i) a non existing file, ii) a privilege violation (the user has not write access to the output file), or iii) the file may also be locked by another user.
User action : If you want to create a new output file, specify the 3$^{rd}$ argument NEW to the FILE OUT command.
F-OUTPUT, Read error file <String>
LAS, FILE OUT command. The specified file could be opened, but most likely is not a CLASS data file.
User action : verify the file name, which may have been mistyped. If it is correct, notify your system manager because the error is due to a hardware problem.
E-PEN, Number outside boundaries 0 - 15
E-PEN, Default pen not changed
LAS, PENCIL command. A bad pen number was specified, the pen number is left unchanged.
W-PEN, Colour outside boundaries 0 - <Integer>
W-PEN, Default colour 0 used
LAS, PENCIL command. A bad colour index has been specified, the colour index is reset to the default value 0.
W-PEN, Dashed pattern outside boundaries 1 - 7
W-PEN, Default dashed pattern 1 used
LAS, PENCIL command. A bad dashed pattern has been specified, the dash pattern is reset to the default value 1 (continuous line).
W-POLYNO, Baseline extrapolation is hazardous
LAS, BASE command. Some of the line windows touch the spectrum edges, so that the baseline must be extrapolated in this range. Extrapolation is made by assuming a constant value in the range, and not by using the polynom because the solution is unstable.
User action : If possible, try to avoid such situations by having a few channels free of lines at the spectrum edges. Note that the extrapolation is most likely incorrect.
W-POLYNO, Degree <Integer> would be even better
LAS, BASE command. The specified degree would have given as good a fit to the baseline. It is hence possible that the current degree is too high and creates spurious oscillations.
E-POLYNO, NAG Error in <String>, ifail = <Integer>
LAS, BASE command. The minimization failed or the minimum is ill-defined.
User action : try to change the degree of the baseline, or the definition of the line windows to obtain a better solution.
W-PRINT, At entry <Integer> Scan <Integer>;<Integer>
ANALYSE, PRINT command. The information to be listed is missing or incomplete for the specified scan. This message is usually preceded by ``W-RSEC, Absent section <Integer>''
E-PRINT, Cannot print <String>
ANALYSE, PRINT command. The specified keyword is not (yet) recognized.
E-PRINT, No input file connected
ANALYSE, PRINT command. There is nothing to print...
E-PRINT, Option /TABLE invalid for FIT
ANALYSE, PRINT command. FIT results cannot be written to a GILDAS table, but only to a formatted file.
E-PRINT, No channel list
ANALYSE, PRINT CHANNEL command. The channel list is missing or incorrectly given.
E-PRINT, Syntax error in list : <String>
E-PRINT, Invalid list : <Integer> TO <Integer> BY <Integer>
E-PRINT, Incomplete list : <String>
E-PRINT, Empty list
ANALYSE, PRINT command (possibly with the CHANNEL argument). The list is incorrect in some way.
User action : Correct the faulty list and resubmit the command.
W-PRINT, Too many channels, list truncated
ANALYSE, PRINT CHANNEL command. The channel list is too long and has been truncated.
User action : check the output file to see which channels are missing and use another PRINT command to list the missing channels.
E-PRINT, Too many arguments in list
ANALYSE, PRINT command for velocity ranges. There are too many velocity ranges specified.

E-PRINT, Unable to open file <String>
ANALYSE, PRINT command with /OUTPUT option. The output file could not be created, possibly because of open file quota, disk quota, privilege violation to the directory, or simply invalid file name.


next up previous contents index
Next: R Up: LAS and ANALYSE Messages Previous: M   Contents   Index
Gildas manager 2014-07-01