next up previous contents index
Next: SET SCAN Up: SET Previous: SET REFERENCE   Contents   Index


SET RF_PASSBAND

        CLIC\SET RF_PASSBAND [ON|OFF] [CHANNEL|FREQUENCY]
        [FILE|MEMORY] [ANTENNA|BASELINE]

    This command controls the behaviour of CLIC regarding  the  RF  passband
    calibration.

    SET RF_PASSBAND ON|OFF

        Switch ON or OFF the application of RF passband calibration curve in
        plotting the data.  The RF passband calibration curve is computed by
        SOLVE  RF_PASSBAND  and  stored  with the data by STORE RF_PASSBAND.
        Subsequent PLOT commands will use or not this curve according to the
        status of SET RF_PASSBAND ON|OFF.

    SET RF_PASSBAND CHANNEL|FREQUENCY

        Use  either  the  channel dependent passband curves or the frequency
        dependent passband curve.   The  channel-dependent  passband  curves
        must be determined separately for each subband, while the frequency-
        dependent passband curve is determined by using SOLVE RF_PASSBAND on
        all  subbands  together (Note: this will not work for data taken be-
        fore July 14th 1990). SET RF_PASSBAND FREQUENCY is recommended.

    SET RF_PASSBAND MEMORY|FILE

        Use either the passband curves just determined by SOLVE RF_PASSBAND,
        and still present in the program memory, or the passband curves pre-
        viously stored in the data headers of the input file  by  a  command
        STORE RF_PASSBAND.

    SET RF_PASSBAND ANTENNA|BASELINE

        Switch between Antenna-based and Baseline-based RF passband calibra-
        tions. This switch will be active for  SOLVE  RF_PASSBAND  (passband
        determination),  STORE RF_PASSBAND (passband storing operation), and
        SET RF_PASSBAND ON (fpassband application).  Both baseline-based and
        antenna-based calibration curves may be stored alongside in the data
        header, independently of each other. SET RF_PASSBAND ANTENNA is rec-
        ommended.


Gildas manager 2014-07-01