STORE PHASE
CLIC\STORE PHASE [/BAND code] [/SELF] [/RECEIVER irec]
*** THIS HELP HAS NOT BEEN UPDATED FOR THE NGRX ***
Store the phase calibration determined by the last SOLVE PHASE command.
One calibration curve is stored for each sideband. With option "/BAND
code", one may use the calibration curve determined with one of the
sidebands (`code' is UPPER or USB, LOWER or LSB, or AVERAGE or DSB), to
calibrate both sidebands.
With option "/SELF", the calibration stored will not be the calibration
curve (as determined from the last SOLVE PHASE command) but, for each
scan, the visibility corresponding to the first subband set (eg., SET
SUB L01 to L03 ...); data from each side band will be used to calibrate
the same side band. This provide a simple, easy way to self-calibrate
data taken on strong continuum sources (quasars).
With option "/RECEIVER irec", the calibration curves solved using data
from receiver "irec" will be stored in parallel with any other calibra-
tion curve. This phase curve will be selected by giving SET PHASE EX-
TERNAL (see this command). In practice, this is used for Receiver 2 da-
ta, for which the calibration curve determined with Receiver 1 is
stored. /BAND may be used in conjunction with /RECEIVER.
STORE PHASE and STORE AMPLITUDE can be performed simultaneously using
STORE AMPLITUDE PHASE [/BAND code] [/SELF] [/RECEIVER irec] (the /RE-
CEIVER option has no meaning for amplitudes).