Next: Noise estimation and plotting
Up: Cookbook for the impatient
Previous: Imaging and deconvolution pipeline
Contents
Index
1 lut rainbow3
2 read uv 1mm
3 uv_show
4 uv_stat weight
5 input uv_map
6 let weight_mode UN
7 let uv_cell 7.5 1
8 uv_map
9 show beam
10 show dirty
11 input clean
12 let niter 1000
13 hogbom /flux 0 0.6
14 show residual
15 let niter 2000
16 hogbom /flux 0 0.6
17 show residual
18 let niter 4000
19 hogbom /flux 0 0.6
20 show residual
21 show clean
22 support
23 hogbom /flux 0 0.6
24 show residual
25 show clean
26 write beam 1mm
27 write dirty 1mm
28 write clean 1mm
29 write residual 1mm
30 write cct 1mm
31 exit
Comments:
- Step 1
- Select a color lookup table which nicely displays the
features of the studied source.
- Step 2
- Read
data from the 1mm.uvt file to an internal
MAPPING buffer.
- Step 3
- Displays the scatter plot of the amplitude vs spatial
frequency of the
visibilities. This commands is similar to the
GO UVALL command (see previous section), except that it works
only on the data previously loaded in the internal buffer.
- Step 4
- Predicts the synthesized beam, expected noise level, and
recommended pixel size for different values of the robust weighting
threshold. This helps the user to select the threshold used in the
imaging steps (2nd parameter of the uv_cell variable).
- Steps 5-10
- Compute a tailored dirty beam and dirty image. Step 5
displays the SIC variables that customizes the behavior of the
UV_MAP command. Step 6 and 7 selects robust weighting (instead of
the default natural weighting) and the associated threshold. Step 8
actually computes the results which are stored in internal buffers and
visualized in steps 9 and 10.
- Steps 11-14
- First deconvolution on internal buffers. Resulting clean
residuals, clean image and clean component tables are also stored in
internal buffers. Step 11 displays the SIC variables that customizes
the behavior of all the clean deconvolution algorithms. Steps 12 select
the stopping criterion by enabling a maximum of 1000 clean components.
Step 13 launches the deconvolution using the simplest CLEAN algorithm
with simultaneous plot of the cumulative flux as a function of the number
of found clean components. Step 14 displays the residuals, i.e. remaining
undeconvolved signal.
- Steps 15-24
- Successive tries of the deconvolution to ensure deep
enough cleaning, just by changing the stopping criterion (here the total
number of clean components).
- Step 25
- Displays the resulting clean image.
- Steps 26-30
- Write the results (dirty beam, dirty image, clean image,
clean residuals and clean component table) on disk files for use in
future sessions.
Next: Noise estimation and plotting
Up: Cookbook for the impatient
Previous: Imaging and deconvolution pipeline
Contents
Index
Gildas manager
2014-07-01