Next: VIEW
Up: MIRA language internal help
Previous: SOLVE
Index
VARIABLE
MIRA\VARIABLE section|* read|write
Generates a SIC copy of one of the following MIRA data sections
(wildcard permitted, activates all sections), for read (default)
ow write access. For further documentation on MIRA’s data structure,
please consult section 5 of the MIRA manual. The section MON consists of
SIC structures MON%HEADER and MON%DATA. Each frontend-backend
combination has its own GAINS and REDUCE section (e.g. GAINS1, REDUCE3,
etc.). The sections SCAN, FEBE, and DATA consist of header and data
structures for each frontend-backend combination, e.g. SCAN1%HEADER,
SCAN1%DATA, FEBE2%HEADER, FEBE3%DATA, and so on. The DATA and HEADER
structures of section ARRAY are written for each baseband, e.g.
ARRAY1%HEADER1, ARRAY2%DATA3, etc.
VARIABLE PRIM Retrieves the IMBFITS primary header.
VARIABLE SCAN Same for the scan header and table sections.
VARIABLE FEBE Information related to the frontend-backend combination.
VARIABLE ARRAY Raw data headers and data sections.
VARIABLE DATA For calibrated raw data, and monitor points interpolated
at the backend timestamps.
VARIABLE MON Monitoring headers and table sections.
VARIABLE GAINS Calibration parameter for each frontend-backend
combination.
VARIABLE CHOICE Search options for MIRA’s command FIND.
VARIABLE REDUCE MIRA internal flags for calibration history.
VARIABLE LIST Entries of the current index list.
Gildas manager
2014-07-01